			<item>
		<title>PowerQ is part of Commissioining Team at Marina Bay Sands Integrated Luxury Resort, Singapore</title>
		<link>http://powerqtech.com/news/powerq-is-part-of-commissioining-team-at-marina-bay-sands-integrated-luxury-resort-singapore</link>
		<comments>http://powerqtech.com/news/powerq-is-part-of-commissioining-team-at-marina-bay-sands-integrated-luxury-resort-singapore#comments</comments>
		<pubDate>Thu, 10 Jun 2010 06:35:58 +0000</pubDate>
		<dc:creator>admin</dc:creator>
				<category><![CDATA[News]]></category>

		<guid isPermaLink="false">http://powerqtech.com/news/powerq-is-part-of-commissioining-team-at-marina-bay-sands-integrated-luxury-resort-singapore</guid>
		<description><![CDATA[The  Marina Bay Sands (MBS ) Singapore  www.marinabaysands.com   is developed by one of the world&#8217;s biggest entertainment companies, Las Vegas Sands, at Marina Bay waterfront in central Singapore.  We are perform the T&#38;C work to MBS representative satisfaction under the general supervision and direction of the MBS, Consultants  and our clients.
]]></description>
			<content:encoded><![CDATA[<p>The  Marina Bay Sands (MBS ) Singapore  <span><cite><a href="http://www.marinabaysands.com">www.<strong>marinabaysands</strong>.com</a>  </cite></span> is developed by one of the world&#8217;s biggest entertainment companies, Las Vegas Sands, at Marina Bay waterfront in central Singapore.  We are perform the T&amp;C work to MBS representative satisfaction under the general supervision and direction of the MBS, Consultants  and our clients.</p>
]]></content:encoded>
			<wfw:commentRss>http://powerqtech.com/news/powerq-is-part-of-commissioining-team-at-marina-bay-sands-integrated-luxury-resort-singapore/feed</wfw:commentRss>
		<slash:comments>0</slash:comments>
		</item>
		<item>
		<title>PowerQ is part of Commissioining Team at Marina Bay Sands Integrated Luxury Resort, Singapore</title>
		<link>http://powerqtech.com/case-study/powerq-is-part-of-commissioing-team-at-marina-bay-sands-integrated-resort-singapore</link>
		<comments>http://powerqtech.com/case-study/powerq-is-part-of-commissioing-team-at-marina-bay-sands-integrated-resort-singapore#comments</comments>
		<pubDate>Mon, 31 May 2010 11:17:20 +0000</pubDate>
		<dc:creator>editor</dc:creator>
				<category><![CDATA[Case Studies]]></category>
		<category><![CDATA[Facility O&M Services & Solutions]]></category>
		<category><![CDATA[Testing and Commissioning Services and Solutions]]></category>

		<guid isPermaLink="false">http://powerqtech.com/?p=423</guid>
		<description><![CDATA[The Marina Bay Sands (MBS ) www.marinabaysands.com   is developed by one of the world&#8217;s biggest entertainment companies, Las Vegas Sands, at Marina Bay waterfront in central Singapore.  We are perform the T&#38;C work to MBS representative satisfaction under the general supervision and direction of the MBS, Consultants  and our clients.
 
 
Since August 09 PowerQ has been involved [...]]]></description>
			<content:encoded><![CDATA[<p align="left">The Marina Bay Sands (MBS ) <span><cite><a href="http://www.marinabaysands.com">www.<strong>marinabaysands</strong>.com</a>  </cite></span> is developed by one of the world&#8217;s biggest entertainment companies, Las Vegas Sands, at Marina Bay waterfront in central Singapore.  We are perform the T&amp;C work to MBS representative satisfaction under the general supervision and direction of the MBS, Consultants  and our clients.</p>
<p align="left"> <a href="http://powerqtech.com/wp-content/uploads/2010/05/MARINA-BAY-SANDS-3-XHotel-Towers1.jpg"><img class="alignnone size-medium wp-image-467" title="MARINA BAY SANDS, Singapore ,  Hotel Towers" src="http://powerqtech.com/wp-content/uploads/2010/05/MARINA-BAY-SANDS-3-XHotel-Towers1-300x227.jpg" alt="MARINA BAY SANDS, Singapore ,  Hotel Towers" width="300" height="227" /></a></p>
<p align="left"> </p>
<p>Since August 09 PowerQ has been involved in HVAC testing and commissioing in  following areas:</p>
<ul>
<li>3x 57 Storey hotel  towers with about 3000 rooms</li>
<li>Casino and retail area</li>
</ul>
<p>PowerQ has provided caliberated instrument and experianced tesm of enginners, document controller and technicians to test thousands of equipments . PowerQ have performed T&amp;C of life  safety system such as staircase pressurisation, exhaust ventilation IAQ system for casino, AHU and FCU system for hotels, casino and  retail area. PowerQ is part of commissioing team lead by MBS and its consultants and contractors.<br />
The finetuning of T&amp;C  work shall continue  till 3rd quarter of this 2010 and PowerQ is ensuring to provide a comfortable, safe and efficient facility.</p>
]]></content:encoded>
			<wfw:commentRss>http://powerqtech.com/case-study/powerq-is-part-of-commissioing-team-at-marina-bay-sands-integrated-resort-singapore/feed</wfw:commentRss>
		<slash:comments>0</slash:comments>
		</item>
		<item>
		<title>Vibration Monitoring at OYO field FPSO</title>
		<link>http://powerqtech.com/case-study/testing-commissioning/vibration-monitoring-at-oyo-field-fpso</link>
		<comments>http://powerqtech.com/case-study/testing-commissioning/vibration-monitoring-at-oyo-field-fpso#comments</comments>
		<pubDate>Mon, 31 May 2010 09:46:54 +0000</pubDate>
		<dc:creator>editor</dc:creator>
				<category><![CDATA[Testing and Commissioning Services and Solutions]]></category>

		<guid isPermaLink="false">http://powerqtech.com/?p=418</guid>
		<description><![CDATA[The E House contractor  has  installed  HVAC packages on Ehouse and was  concerned about high vibration level  before starting up the system. The contractor SPL has commissioined  PowerQ to perform vibration measurement at Compressor and AHU compare against benchmarks and  advise practical solutions to mitigate the impending problem.
Our enginners  reviewed the installtion drawing,  alignment and factory report [...]]]></description>
			<content:encoded><![CDATA[<p>The E House contractor  has  installed  HVAC packages on Ehouse and was  concerned about high vibration level  before starting up the system. The contractor SPL has commissioined  PowerQ to perform vibration measurement at Compressor and AHU compare against benchmarks and  advise practical solutions to mitigate the impending problem.</p>
<p>Our enginners  reviewed the installtion drawing,  alignment and factory report and conducted  Vibration verification measurement on  AHU and Chiller Compressor and Wall Mounted Condenser  Axial Fans  at following location :</p>
<p>Compressor</p>
<p>Condenser  Fans</p>
<p>AHU blower<span id="_marker"> </span></p>
<p class="MsoBodyText3" style="margin: 6pt 0in 0pt; mso-layout-grid-align: none; tab-stops: .5in;">The result of measuremnt was use to mitigate the excessive vibration levels and helped to avid any failure of critical system while the vessel is performing offshore  production.</p>
]]></content:encoded>
			<wfw:commentRss>http://powerqtech.com/case-study/testing-commissioning/vibration-monitoring-at-oyo-field-fpso/feed</wfw:commentRss>
		<slash:comments>0</slash:comments>
		</item>
		<item>
		<title>Lightning Protection review for CPP in Natuna Sea</title>
		<link>http://powerqtech.com/case-study/lighning-protection-review-for-cpp-in-natuna-sea</link>
		<comments>http://powerqtech.com/case-study/lighning-protection-review-for-cpp-in-natuna-sea#comments</comments>
		<pubDate>Mon, 31 May 2010 09:18:21 +0000</pubDate>
		<dc:creator>editor</dc:creator>
				<category><![CDATA[Case Studies]]></category>
		<category><![CDATA[Projects Engineering and Design Services]]></category>

		<guid isPermaLink="false">http://powerqtech.com/?p=407</guid>
		<description><![CDATA[GB  Project (WP and CPP) location is in an open sea with relatively high lightning activity. When completed this  project shall bring gas to Singapore through a 300km subsea pipeline. The facilities at WP and CPP are electrical system, radio telecommunication system (VSAT), Instrumentation system and pipelining. The electrical system is in construction stage. A  lightning [...]]]></description>
			<content:encoded><![CDATA[<p><strong>GB </strong> Project (WP and CPP) location is in an open sea with relatively high lightning activity. When completed this  project shall bring gas to Singapore through a 300km subsea pipeline. The facilities at WP and CPP are electrical system, radio telecommunication system (VSAT), Instrumentation system and pipelining. The electrical system is in construction stage. A  lightning protection design is completed by client. powerQ was requested to review design and provide practicle recommendation for site implementation considering practical installation  difficulties.</p>
<p>2. Project Description</p>
<p>Two GTGs, one duty and one standby, are provided at CPP as main power generation.  CPP and WP are steel structures of which all major structural components are intended welded firmly to deck. The earth bars are intended to be bonded to platform legs.</p>
<p> 3. Objective and Scope</p>
<p>This review was intended to address the need for lightning protection and electronic surge protection on CPP  and WP. PowerQ Technology Pte Ltd was asked by EPC contractor to carry out a comprehensive evaluation of  design  and existing design of Lightning and earthing Protection System and make practical recommendation considering that the construction is ongoing.</p>
<p> The objectives of the lightning protection review study was to</p>
<ul>
<li>Review the design and  recommendation 
<ul>
<li>To review  whether external lightning  terminal are required</li>
<li>To review extend of SPD,s necessary and required</li>
</ul>
</li>
<li>Review the proposed  lightning protection system against standards</li>
<li>Suggest suitable practical recommendation based on current project status.</li>
</ul>
<p> To address objectives PowerQ had undertaken following tasks:</p>
<p> a)     Review of Design and specifications</p>
<p>b)    Review Offshore code and standard</p>
<p>c)     Review of various lightning protection measures</p>
<p>d)     Review of current practice in offshore installation</p>
<p> The intent of review is to provide practical  guidance and not to emphasis on theory of lightning.  PowerQ evaluated several offshore installtion design and provided the best implementable Option to adopt and provide sufficient justifications for the recommendation thus meeting codes but minimising cost of installtion.</p>
<p>The work was performed in 2010 and shall be under continious review . PowerQ is also providing Power System Studies for this project and shall be providing services to client till 2011 as per contract.</p>
]]></content:encoded>
			<wfw:commentRss>http://powerqtech.com/case-study/lighning-protection-review-for-cpp-in-natuna-sea/feed</wfw:commentRss>
		<slash:comments>0</slash:comments>
		</item>
		<item>
		<title>O&amp;M Manual  development for Applied Material (AMAT)  Plant</title>
		<link>http://powerqtech.com/case-study/engineering-design/om-manual-development-for-applied-material-plant</link>
		<comments>http://powerqtech.com/case-study/engineering-design/om-manual-development-for-applied-material-plant#comments</comments>
		<pubDate>Mon, 31 May 2010 07:56:59 +0000</pubDate>
		<dc:creator>editor</dc:creator>
				<category><![CDATA[Projects Engineering and Design Services]]></category>

		<guid isPermaLink="false">http://powerqtech.com/?p=387</guid>
		<description><![CDATA[   To complement T&#38;C work, PowerQ was asked by Main contractor Taikisha  provide additional support  to write O&#38;M Manual for HVAC  system for new grennfield plant at Changi south.  To meet high standard of Applied material project the  remit was to produce a narrative and illustrative document and not merely compilation of drawing, specs and catalogues [...]]]></description>
			<content:encoded><![CDATA[<p><a href="http://powerqtech.com/wp-content/uploads/2010/05/IMG00807-20091218-1805.jpg"><img class="alignnone size-thumbnail wp-image-484" title="IMG00807-20091218-1805" src="http://powerqtech.com/wp-content/uploads/2010/05/IMG00807-20091218-1805-150x150.jpg" alt="IMG00807-20091218-1805" width="150" height="150" /></a>   To complement T&amp;C work, <strong>PowerQ</strong> was asked by Main contractor Taikisha  provide additional support  to write O&amp;M Manual for HVAC  system for new grennfield plant at Changi south.  To meet high standard of Applied material project the  remit was to produce a narrative and illustrative document and not merely compilation of drawing, specs and catalogues as usually practiced.</p>
<p><strong>PowerQ</strong> commissioing enginners discussed the operation with the clients enginners, collected equipement data , drawings, specification and reviewed physical system and  prepared O&amp; M Manuals comprising of   three sections  SYSTEM DESCRIPTION ,  SYSTEM OPERATION  and  SYSTEM MAINTENENCE. Extensive used of flowchart and simplified layout drawing was made to easy understanding.</p>
<p>Special emphasis was laid to safe operation and energy efficient O&amp;M  procedure. The manual was produced in hardcopy and indexed pdf softcopy. The information in manual shall be further used for scheduling predictive  maintainence and RCM.</p>
]]></content:encoded>
			<wfw:commentRss>http://powerqtech.com/case-study/engineering-design/om-manual-development-for-applied-material-plant/feed</wfw:commentRss>
		<slash:comments>0</slash:comments>
		</item>
		<item>
		<title>Air Tightness Test (ATT/IOPT)  for MRT Circle Line BV Station</title>
		<link>http://powerqtech.com/case-study/testing-commissioning/air-tightness-test-an-internal-overpressure-test-for-mrt-circle-line-station</link>
		<comments>http://powerqtech.com/case-study/testing-commissioning/air-tightness-test-an-internal-overpressure-test-for-mrt-circle-line-station#comments</comments>
		<pubDate>Mon, 31 May 2010 07:33:52 +0000</pubDate>
		<dc:creator>editor</dc:creator>
				<category><![CDATA[Testing and Commissioning Services and Solutions]]></category>

		<guid isPermaLink="false">http://powerqtech.com/?p=382</guid>
		<description><![CDATA[
 
A new underground MRT line called as circle line is being constructed in Singapore. As certified testing company PowerQ worked with SETSCO services and assited the main contractor to conduct a crucial testing by pressuring the entire building like a balloon.  The purpose of the ATT is to provide an indication if the Civil Defense Shelter [...]]]></description>
			<content:encoded><![CDATA[<p style="TEXT-ALIGN: justify; LINE-HEIGHT: 14.25pt; MARGIN: 0in 0in 0pt"><span style="FONT-FAMILY: 'Lucida Sans Unicode','sans-serif'; FONT-SIZE: 10pt"><a href="http://powerqtech.com/wp-content/uploads/2010/05/DSC00385.JPG"><img class="alignnone size-full wp-image-469" title="PRESSURISATION TEST OF BV STATION" src="http://powerqtech.com/wp-content/uploads/2010/05/DSC00385.JPG" alt="PRESSURISATION TEST OF BV STATION" width="200" height="150" /></a></span></p>
<p style="TEXT-ALIGN: justify; LINE-HEIGHT: 14.25pt; MARGIN: 0in 0in 0pt"><span style="FONT-FAMILY: 'Lucida Sans Unicode','sans-serif'; FONT-SIZE: 10pt"> </span></p>
<p style="TEXT-ALIGN: justify; LINE-HEIGHT: 14.25pt; MARGIN: 0in 0in 0pt"><span style="FONT-FAMILY: 'Lucida Sans Unicode','sans-serif'; FONT-SIZE: 10pt">A new underground MRT line called as circle line is being constructed in Singapore. As certified testing company PowerQ worked with SETSCO services and assited the main contractor to conduct a crucial testing by pressuring the entire building like a balloon.  The purpose of the ATT is to provide an indication if the Civil Defense Shelter and all its mechanical penetrations and closure devices are airtight against the penetration of air from outside. </span></p>
<p style="TEXT-ALIGN: justify; LINE-HEIGHT: 14.25pt; MARGIN: 0in 0in 0pt"><span style="FONT-FAMILY: 'Lucida Sans Unicode','sans-serif'; FONT-SIZE: 10pt"> </span></p>
<p style="TEXT-ALIGN: justify; LINE-HEIGHT: 14.25pt; MARGIN: 0in 0in 0pt"><span style="FONT-FAMILY: 'Lucida Sans Unicode','sans-serif'; FONT-SIZE: 10pt"> </span></p>
<p style="TEXT-ALIGN: justify; LINE-HEIGHT: 14.25pt; MARGIN: 0in 0in 0pt"><span style="FONT-FAMILY: 'Arial','sans-serif'">One of the most challenginning part of the work waas erfomed by construction team by sealing any gaps in thousand of sqare meter of serface area including all the penetrations for utilities and human and train  access though tunnel. This test allowed  for the easy detection of leaks from Blast Doors, Blast Valves Sleeves/Frames, Protective/Hardened Structures, Sealing Devices and etce. The entire volume 4 storey structure measuring more than 10,000 sq m was presssurised with a fan with caliberated venturi for measuremnt of flow. The flow and pressure was monitored over duration of test with data loggers and digital instrumentation specially configured for test. Hundreds of meter of sensor tubing was run and the pressure drop was compensated by applying correction factors in loggers placed on various floors .</span></p>
<p style="TEXT-ALIGN: justify; LINE-HEIGHT: 14.25pt; MARGIN: 0in 0in 0pt"><span style="FONT-FAMILY: 'Arial','sans-serif'"> </span></p>
<p style="TEXT-ALIGN: justify; LINE-HEIGHT: 14.25pt; MARGIN: 0in 0in 0pt">PowerQ conducted IOPT and ATT tests, conducted within the protected bounds of the Concourse, Platform and Underplatform Levels. The test was witnessed by authorities and passed in first atttemps thanks to extensive preparation, planning and coordination works done by hundreds of staff. Passing of this milestaone   test conducted in 2009 and allowed the JV main contractor  to continue the construction process.</p>
<p style="TEXT-ALIGN: justify; LINE-HEIGHT: 14.25pt; MARGIN: 0in 0in 0pt"> </p>
<p style="TEXT-ALIGN: justify; LINE-HEIGHT: 14.25pt; MARGIN: 0in 0in 0pt">PowerQ has conducted similar tests for facilities such as Isolation and OT rooms in hospitals, Blast proof rooms in oil rigs ,  Halon Pressurised room in Data Centres and BSL negative pressurised rooms in animal holding facilities/Vivariums  and BSL labs .</p>
]]></content:encoded>
			<wfw:commentRss>http://powerqtech.com/case-study/testing-commissioning/air-tightness-test-an-internal-overpressure-test-for-mrt-circle-line-station/feed</wfw:commentRss>
		<slash:comments>0</slash:comments>
		</item>
		<item>
		<title>Failure of Fan Filter units due suspected strong EMF from Superconducting Magnetic Sources</title>
		<link>http://powerqtech.com/case-study/failure-of-fan-filter-units-due-suspected-strong-emf-from-superconducting-magnetic-sources</link>
		<comments>http://powerqtech.com/case-study/failure-of-fan-filter-units-due-suspected-strong-emf-from-superconducting-magnetic-sources#comments</comments>
		<pubDate>Mon, 31 May 2010 03:03:56 +0000</pubDate>
		<dc:creator>editor</dc:creator>
				<category><![CDATA[Case Studies]]></category>
		<category><![CDATA[Facility O&M Services & Solutions]]></category>

		<guid isPermaLink="false">http://powerqtech.com/?p=379</guid>
		<description><![CDATA[In 2009 , PowerQ  conducted an Electromagnetic Field survey emitted from crystal growth furnace  to find out level of interference that caused to damage several Fan Filter Unit (FFU) at new Wafer plant, Tampines , Singapore.
Enginners from PowerQ installed EMF data logger  to measure and monitor with data logger to generate a clear picture of [...]]]></description>
			<content:encoded><![CDATA[<p>In 2009 , PowerQ  conducted an Electromagnetic Field survey emitted from crystal growth furnace  to find out level of interference that caused to damage several Fan Filter Unit (FFU) at new Wafer plant, Tampines , Singapore.</p>
<p>Enginners from PowerQ installed EMF data logger  to measure and monitor with data logger to generate a clear picture of EMF emissions in the areas over time and capture any peak values.  The data was recorded for several weeks and at interval of 1 mnute undered varied operating condion . PowerQ provided  observation status and re-measured EMF  after the proposed measures had been implemented to analyze the collective information of EMF interference bymminimum and maximum field strength readings.</p>
]]></content:encoded>
			<wfw:commentRss>http://powerqtech.com/case-study/failure-of-fan-filter-units-due-suspected-strong-emf-from-superconducting-magnetic-sources/feed</wfw:commentRss>
		<slash:comments>0</slash:comments>
		</item>
		<item>
		<title>PowerQ Provides Enginnering Support for Upgrade of Discoverer Drillship for Arctic Operation</title>
		<link>http://powerqtech.com/news/powerq-provides-enginnering-support-for-upgrade-of-discoverer-drillship-for-arctic-operation</link>
		<comments>http://powerqtech.com/news/powerq-provides-enginnering-support-for-upgrade-of-discoverer-drillship-for-arctic-operation#comments</comments>
		<pubDate>Mon, 31 May 2010 00:24:39 +0000</pubDate>
		<dc:creator>editor</dc:creator>
				<category><![CDATA[News]]></category>

		<guid isPermaLink="false">http://powerqtech.com/?p=355</guid>
		<description><![CDATA[In first quarter of  2010, PowerQ performed a study to upgrade power system for Dicoverer drillship ungergoing massive upgrade of electrical power system  at vessel docked at Subic bay, Philippines. PowerQ  enginners embarked on  data collection of site  and future power neeeds of the operation.

 Based input parameters validated by drilling and operation crew  a model was [...]]]></description>
			<content:encoded><![CDATA[<p style="text-align: left;">In first quarter of  2010, PowerQ performed a study to upgrade power system for Dicoverer drillship ungergoing massive upgrade of electrical power system  at vessel docked at Subic bay, Philippines. PowerQ  enginners embarked on  data collection of site  and future power neeeds of the operation.</p>
<p style="text-align: left;"><a href="http://powerqtech.com/wp-content/uploads/2010/05/IMG01250-20100417-0830.jpg"><img class="alignnone size-thumbnail wp-image-478" title="IMG01250-20100417-0830" src="http://powerqtech.com/wp-content/uploads/2010/05/IMG01250-20100417-0830-150x150.jpg" alt="IMG01250-20100417-0830" width="150" height="150" /></a></p>
<p> Based input parameters validated by drilling and operation crew  a model was simulated the electrical generation and power system and  estimate power requiremnt for drilling operation. The Protection setting for new geerator circuit braeakers and various loads including mudpumps, topdrive and ship services transfomer were recalculated and  relay set by Frontier Drilling team.</p>
]]></content:encoded>
			<wfw:commentRss>http://powerqtech.com/news/powerq-provides-enginnering-support-for-upgrade-of-discoverer-drillship-for-arctic-operation/feed</wfw:commentRss>
		<slash:comments>0</slash:comments>
		</item>
		<item>
		<title>Invitation for Application  for Electrical and Control Engineer</title>
		<link>http://powerqtech.com/jobs/invitation-for-application-for-electrical-and-control-enginneers</link>
		<comments>http://powerqtech.com/jobs/invitation-for-application-for-electrical-and-control-enginneers#comments</comments>
		<pubDate>Sun, 30 May 2010 22:55:53 +0000</pubDate>
		<dc:creator>editor</dc:creator>
				<category><![CDATA[Jobs]]></category>

		<guid isPermaLink="false">http://powerqtech.com/?p=349</guid>
		<description><![CDATA[Qualification:

Good Enginnering Degree/Diploma  with minimum 2 years project experiance with EPC or Contractors
Singapore resident -Singaporean/PR
Willing to travel in Asia Pacific  region

 
Work Scope:

Enginnering Design  using application software &#8211; ETAP, SKM, E3, Autocad, Luxicon
Site Testing and commissioing for HT/LT Relays, Circuit breakers and switchgears
Power Management System Enginnering
Power Quality Audit and Monitoring using Digital loggers
Third Party Design Reviews 
Site [...]]]></description>
			<content:encoded><![CDATA[<p>Qualification:</p>
<ul>
<li>Good Enginnering Degree/Diploma  with minimum 2 years project experiance with EPC or Contractors</li>
<li>Singapore resident -Singaporean/PR</li>
<li>Willing to travel in Asia Pacific  region</li>
</ul>
<p> </p>
<p>Work Scope:</p>
<ul>
<li>Enginnering Design  using application software &#8211; ETAP, SKM, E3, Autocad, Luxicon</li>
<li>Site Testing and commissioing for HT/LT Relays, Circuit breakers and switchgears</li>
<li>Power Management System Enginnering</li>
<li>Power Quality Audit and Monitoring using Digital loggers</li>
<li>Third Party Design Reviews </li>
<li>Site Services Project Management</li>
<li>prepartion of O&amp;M  Manuals</li>
</ul>
]]></content:encoded>
			<wfw:commentRss>http://powerqtech.com/jobs/invitation-for-application-for-electrical-and-control-enginneers/feed</wfw:commentRss>
		<slash:comments>0</slash:comments>
		</item>
		<item>
		<title>PowerQ is providing Detailed Enginnering Services for greenfield offshore Production Yard</title>
		<link>http://powerqtech.com/news/powerq-is-providing-enginnering-services-for-greenfield-offshore-production-yard</link>
		<comments>http://powerqtech.com/news/powerq-is-providing-enginnering-services-for-greenfield-offshore-production-yard#comments</comments>
		<pubDate>Sun, 30 May 2010 22:16:11 +0000</pubDate>
		<dc:creator>editor</dc:creator>
				<category><![CDATA[News]]></category>

		<guid isPermaLink="false">http://powerqtech.com/?p=346</guid>
		<description><![CDATA[Since early 2009  PowerQ is  providing enginnering services  to  Italian EPC company responsible for construction of a massive state of art fabrication yard in Karimun, Riau Islands, Indonesia .
 
 
The work include electrical and piping enginner for electrical system consiting of more than 24 nos, HV electrical substation spread accross site and several kilometers of compressed air, [...]]]></description>
			<content:encoded><![CDATA[<p>Since early 2009  PowerQ is  providing enginnering services  to  Italian EPC company responsible for construction of a massive state of art fabrication yard in Karimun, Riau Islands, Indonesia .</p>
<p> <a href="http://powerqtech.com/wp-content/uploads/2010/05/IMG00041-20090807-17081.jpg"><img class="alignnone size-thumbnail wp-image-480" title="IMG00041-20090807-1708" src="http://powerqtech.com/wp-content/uploads/2010/05/IMG00041-20090807-17081-150x150.jpg" alt="IMG00041-20090807-1708" width="150" height="150" /></a><a href="http://powerqtech.com/wp-content/uploads/2010/05/IMG01135-20100315-1415.jpg"><img class="alignnone size-thumbnail wp-image-481" title="IMG01135-20100315-1415" src="http://powerqtech.com/wp-content/uploads/2010/05/IMG01135-20100315-1415-150x150.jpg" alt="IMG01135-20100315-1415" width="150" height="150" /></a><a href="http://powerqtech.com/wp-content/uploads/2010/05/IMG01137-20100315-14151.jpg"><img class="alignnone size-thumbnail wp-image-482" title="IMG01137-20100315-1415" src="http://powerqtech.com/wp-content/uploads/2010/05/IMG01137-20100315-14151-150x150.jpg" alt="IMG01137-20100315-1415" width="150" height="150" /></a></p>
<p> </p>
<p>The work include electrical and piping enginner for electrical system consiting of more than 24 nos, HV electrical substation spread accross site and several kilometers of compressed air, gases , water utlity piping supplying  essential utilities to buiding designed to produces oil  and gas offshore and subsea systems.</p>
]]></content:encoded>
			<wfw:commentRss>http://powerqtech.com/news/powerq-is-providing-enginnering-services-for-greenfield-offshore-production-yard/feed</wfw:commentRss>